Two Security Vulnerabilities in Genetec Security Center: Critical Authentication Risk with a CVSS Score of 9.8
Records for CVE-2026-124284 and CVE-2026-50048 have been published for Genetec Security Center. The critical authentication vulnerability and the risk of access-control credentials being exposed in logs have been confirmed.
Official records have been published for vulnerabilities CVE-2026-124284 and CVE-2026-50048 affecting Security Center, the platform of Genetec, a provider of enterprise physical security software.
According to information submitted to the CVE Program by Genetec, the first vulnerability has a CVSS 3.1 base score of 9.8, while the second has a score of 7.8.
Both vulnerabilities affect Security Center software running on Windows. However, the affected configurations, security risks, and fixed releases differ.
Organizations operating facilities where video surveillance and access control are managed through centralized software should treat this development as a priority.
CVE-2026-124284: Critical Authentication Vulnerability
According to Genetec’s official CVE record, the vulnerability affects Security Center configurations that use certain external authentication methods.
The affected methods include OpenID Connect (OIDC), SAML 2.0, and Active Directory Federation Services (AD FS) using WS-Trust or WS-Federation.
These technologies allow enterprise applications to verify user identities through a centralized identity provider. This enables employees and system administrators to use the organization’s central identity infrastructure instead of maintaining separate accounts for different applications.
Successful exploitation of the vulnerability could, under certain conditions, allow an attacker to access Security Center with the privileges of an affected user.
The vendor also notes that certain conditions must coincide for an attack to succeed. Therefore, a CVSS score of 9.8 does not mean that every Security Center installation can be exploited in the same way. The authentication method used by the installation and its system configuration must be assessed separately.
Which Security Center Versions Are Affected?
The following version ranges are listed as affected in the CVE-2026-124284 record prepared by Genetec.
5.1: 5.10.0 and later, before 5.10.4.34. The non-affected version threshold in this branch is 5.10.4.34.
5.11: 5.11.0 and later, before 5.11.3.32. The threshold is 5.11.3.32.
5.12: 5.12.0 and later, before 5.12.2.25. The threshold is 5.12.2.25.
5.13: 5.13.0 and later, before 5.13.3.11. The threshold is 5.13.3.11.
5.14.0–5.14.1: 5.14.0 and later, before 5.14.1.4. The threshold is 5.14.1.4.
5.14.2: 5.14.2.0 and later, before 5.14.2.1. The threshold is 5.14.2.1.
In particular, note that Security Center version 5.14.2.0 is listed among the affected versions in the official CVE record.
When preparing an update plan, organizations should consider the full software version and the maintenance branch in use, not just the major version number. These thresholds are based on the vendor’s CVE record. The availability of update packages and compatibility requirements specific to the installation should be confirmed with Genetec technical support.
CVE-2026-50048: Exposure of Access-Control Credentials in Logs
The second vulnerability is related to how Security Center generates server logs. According to Genetec, when certain non-default logging options are enabled, credentials for access-control units may be written to log files in plain text.
An attacker with local access to these files could obtain the credentials in question. Classified under CWE-532, the issue has a CVSS 3.1 base score of 7.8.
The relevant fix is included in Genetec’s Security Center 5.14.0.1 technical update documentation. Although the official CVE record for this vulnerability was published on November 24, some relevant fixes had already been included in earlier software updates.
Therefore, the recent publication of the CVE record does not mean that the vulnerability was discovered today or that all fixes became available today.
Update Releases for the Second Vulnerability
For CVE-2026-50048, Genetec recommends upgrading to Security Center 5.10.4.32, 5.11.3.30, 5.12.2.20, 5.13.3.8, or 5.14.0.1, or to a later supported version in the relevant branch.
Customers using versions that are no longer supported should move to a supported software version.
The vendor recommends using the default logging configuration whenever possible. If additional diagnostic logs are needed, their use should be limited and access to the files protected.
Securely deleting diagnostic files that are no longer needed is also among the vendor’s temporary mitigation recommendations. If a security incident is under investigation, evidence-retention requirements should also be taken into account.
How Do the Two Security Vulnerabilities Differ?
CVE-2026-124284 concerns centralized authentication processes, while CVE-2026-50048 is an issue involving the protection of sensitive information in server logs.
External identity-provider configurations are relevant to the first vulnerability, whereas the second involves enabling specific logging options and local access to log files.
There is no verified attack scenario in which these two vulnerabilities have been exploited together on the same system. In addition, a software version that fixes the second vulnerability should not be assumed to fix the first automatically. Each CVE should be assessed separately when planning updates.
What Should Security Integrators in Türkiye Do?
Airports, industrial facilities, commercial buildings, and other organizations using Security Center should first assess their existing server and software inventories.
Security teams should identify the exact numbers of installed versions, review centralized authentication methods, check which users and service accounts can access server logs, verify vendor updates, test camera feeds, alarm notifications, and access-control functions after updating, and review security logs for signs of possible unauthorized access.
In large-scale physical security projects, the update process should be planned to preserve business continuity and emergency functions.
A previously published story on GüvenlikOnline about the Genetec Security Center MCP connection also highlights the importance of authorization in centralized security management. However, there is no information indicating that the two newly disclosed vulnerabilities stem from the MCP connection.
Is There a Confirmed Attack?
The records reviewed do not confirm a customer data breach resulting from either of these vulnerabilities. This does not mean that the vulnerabilities cannot be exploited. Organizations should assess the vendor’s updates without delay.
Sources
- https://raw.githubusercontent.com/CVEProject/cvelistV5/main/cves/2026/124xxx/CVE-2026-124284.json
- https://raw.githubusercontent.com/CVEProject/cvelistV5/main/cves/2026/50xxx/CVE-2026-50048.json
- https://techdocs.genetec.com/r/en-US/Security-Updates-for-Security-Center-5.14/Resolved-vulnerabilities-in-Security-Center-5.14.0.1
Source: raw.githubusercontent.com